hosted by liquidweb

Showing results 1 to 15 of 209
Search: Posts Made By: NEMON
Forum: Colocation and Data Centers 05-15-2012, 06:58 AM
Replies: 26
Views: 1,643
Posted By NEMON
For that price R410 is just fine. Just be sure...

For that price R410 is just fine. Just be sure you have dual PSU - cause cpu + MB + memory usual dont fail as much, so it's always best to have PSU + hard drives spare and ready.

Again, for that...
Forum: Colocation and Data Centers 05-10-2012, 05:11 PM
Replies: 4
Views: 704
Posted By NEMON
You can look some of the datacentars here ...

You can look some of the datacentars here

http://www.datacentermap.com/

For example it's saying USA have 1100+ (on that map)

But I am sure everything you see on that map - is not even close...
Forum: Dedicated Server 05-07-2012, 04:12 PM
Replies: 41
Views: 3,452
Posted By NEMON
explorator7, why you say 10 TB is not enough...

explorator7,

why you say 10 TB is not enough ? what if each VPS use only 400 GB per month ? More then enough.

Also, traffic is not expensive at hetzner - it's only around 6,90 Euro-ish

ANd...
Forum: Dedicated Server 05-07-2012, 02:23 PM
Replies: 41
Views: 3,452
Posted By NEMON
Well the way to use "maximum" power of something...

Well the way to use "maximum" power of something is to push it to the limit. I have no idea what you running on server so I cant tell you "When you put 100 more domains, that's the limit"

Basicly,...
Forum: Dedicated Server 05-07-2012, 09:52 AM
Replies: 41
Views: 3,452
Posted By NEMON
sameev29 it's better then 2 x 7200 - in RAID...

sameev29

it's better then 2 x 7200 - in RAID 1

So yes, it's better.

But SAS drives ar always better - cause you get more speed.

Check your options to get 10.000 RPM drives or even 15.000...
Forum: Dedicated Server 05-07-2012, 08:23 AM
Replies: 2
Views: 1,506
Posted By NEMON
When we look load on machine we usual use that...

When we look load on machine we usual use that info for "quick" reference to see if something "funky" is goin on at server or not.

You can have load 2.0 - or 20.0 and still server can work OK -...
Forum: Dedicated Server 05-06-2012, 08:38 PM
Replies: 41
Views: 3,452
Posted By NEMON
Yes. This basicly, goes for any kind of setup....

Yes. This basicly, goes for any kind of setup. Your drives will for sure be bottlenecked BIG time.

Time and again, we see clients, just focused on CPU power, then memory, and 90% times nobody even...
Forum: Colocation and Data Centers 05-06-2012, 06:46 PM
Replies: 49
Views: 2,641
Posted By NEMON
porcupine that was actually very funny :)

porcupine that was actually very funny :)
Forum: Dedicated Server 05-06-2012, 06:44 PM
Replies: 41
Views: 3,452
Posted By NEMON
Hello Mr.Zooka, in order to use RAID 10 -...

Hello Mr.Zooka,

in order to use RAID 10 - you need minimum 4 drives, the more drives you use - the better cause of speed.

CPU wise, by "definition" it's always better to have faster CPU's -...
Forum: Dedicated Server 05-06-2012, 05:41 PM
Replies: 41
Views: 3,452
Posted By NEMON
Mr. Zooka, you seem's to be "LOST" in CPU...

Mr. Zooka,

you seem's to be "LOST" in CPU story. Forget the CPU - moste cpu's today ar very powerfull. What others ar telling you is that your IO on hard drives will prevent you to use your CPU...
Sponsored Links
Forum: Colocation and Data Centers 05-06-2012, 11:04 AM
Replies: 49
Views: 2,641
Posted By NEMON
Here is the link to blog: http://ctdoh.tumblr.com...

Here is the link to blog: http://ctdoh.tumblr.com

Very good read.
Forum: Colocation and Data Centers 05-06-2012, 10:09 AM
Replies: 49
Views: 2,641
Posted By NEMON
Hello Number, first best of luck, but trying...

Hello Number,

first best of luck, but trying to build datacentar is SO much more then just trying to buy "connection" to your "space" that you want to setup for small DC

There is cooling,...
Forum: Dedicated Server 05-06-2012, 09:38 AM
Replies: 5
Views: 645
Posted By NEMON
Melwong, IO access on that server is very...

Melwong,

IO access on that server is very high, and your server will be slow. If your memory is using SWAP memory, then upgrade memory and you will improve your IO. If that's not the case, see if...
Forum: Dedicated Server 05-06-2012, 09:22 AM
Replies: 29
Views: 1,969
Posted By NEMON
We use DELL Servers and typical configuration is:...

We use DELL Servers and typical configuration is:

2 x quad (or 6 cores)
32+ GB memory
6 x 400 GB or 12 x 400 GB SAS drives 10k
Hardware RAID 10 (h700 and perc 6i)

We also use 300 GB SAS +...
Forum: Colocation and Data Centers 05-01-2012, 08:21 AM
Replies: 11
Views: 1,109
Posted By NEMON
sorry about that, for some reason I did not type...

sorry about that, for some reason I did not type that as well in first post. Curently, they ar doin around 110-120 Mbit at peak hours, and around 12.000-13.000 connections

Thank you.

I.
Showing results 1 to 15 of 209

 
Forum Jump
Login:
Log in with your username and password
Username:
Password:



Forgot Password?
WHT Host Brief Email:

We respect your privacy. We will never sell, rent, or give away your address to any outside party, ever.

Advertisement:


 

X

Welcome to WebHostingTalk.com

Create your username to jump into the discussion!

WebHostingTalk.com is the largest, most influentual web hosting community on the Internet. Join us by filling in the form below.


(4 digit year)

Already a member?